v1.2.05 24 Feb 2026

Trucheck2 was defaulting to Brother Printer for the USB ASCII output
Code changed so that factory default is "DEF" (TDMS ASCII output)
--------------------------------------------------------------------------------------------------------
v1.2.04 Nov 2025
Brother Printer output format added to USB Commas Protocols 
see  \\fs1\NORBAR\Specials\ETO Project Folders\ETOs 2024\Q5855 - Trucheck 350 Nm portable stand
--------------------------------------------------------------------------------------------------------
V1.2.02 Sep 2022
Own branded products showing 'Norbar Trucheck2' on USB Serial port and USB Serial 'ver' command

Software changed to remove 'Norbar Trucheck2'

Startup message on USB Serial now only shows 'Software Ver xx.xx.xx'
USB Serial command 'ver' now only shows 'Software Ver xx.xx.xx'
--------------------------------------------------------------------------------------------------------
v1.2.0 May 2025
This includes the following changes

Note: These changes are mostly internal production changes or changes for a specific customer

Addition to capacities for Snap-On, Williams and Sturtevant Richmont

Serial out put added output as CSV and TAB as well as a special mode for CAT

Statistics added to log usage (Long press on reset then Units button)




39844 - TRUCHECK 2 MAIN APPLICATION SOFTWARE - 1.1.0 TO 1.2.0 CHANGES :-


Addition to capacities for Snap-On, Williams and Sturtevant Richmont

Serial output added CSV and TAB as well as a special mode for CAT

Statistics added to log usage (Long press on reset then Units button)

39907 - TRUCHECK 2 MAIN APP AND BOOT CODE SOFTWARE - 1.1.0 to 1.2.0 CHANGES :-

Update from version 1.1.0 to version 1.2.0

Update to replace 39844 version 1.1.0 with version 1.2.0 Boot Code remains at version 1.0.2

Send updated 39907 software to Bassett to load onto future batches.

39841 - TRUCHECK 2 PCB ASSY - ISSUE 7 to ISSUE 8 CHANGES :-

Update to replace software loaded from 39907 version 1.1.0 to 39907 version 1.2.0
Update PARTSLIST to reflect this change
Update drawing to reflect this change

Send updated PARTSLIST and drawing to Bassett

Marketing:-
Add new 39844 v1.2.0 software to website
--------------------------------------------------------------------------------------------------------
v1.1.0 March 2020
This includes the following changes

Screen.c - LCD_Range[] was defined to only 8 elements should have been 12 ... This showed up as a problem in the calibration routine corrupting the Cal_Point_D1 value
Screen.c - Range checking added to first Calibration point CW and CCW
Config.c - Default multiplier values changed for each capacity
Screen.c - Calibration Warning screen added to Basic and Plus
Config.c - Config Restore point added to Flash
USB.c    - Serial command to Restore Config added
Main.c   - Check to see if Restore data is there if not current config copied to it (This is bacause the v1.0.1 boot code erases this Restore section if a software update is done)
Maths.c - Default Capacity values changed to fix problem with 1st calibration point instability
--------------------------------------------------------------------------------------------------------
v1.0.3 Oct 2019
This includes the following changes

Overflow value changed to 110% on the 2100Nm model
--------------------------------------------------------------------------------------------------------
v1.0.2 Oct 2019
This includes the following changes

Update to allow reduced gain setting for 2100Nm 
This happens automatically based on the capacity

Calibration flag
Command           rcal                         
reply                      YES if Calibrated
NO is not calibrated

Peak Sensitivity
Command           sensi=n                Sensitivity 0=Low, 1=Medium, 2=High
reply                      OK

Iv also added the following commands that may be useful a some point
eg a French person wants a Trucheck Basics  to check dial wrenches in dN.m with a low sensertivity and a manual reset)
These are all available with out entering the password so Sales could talk a customer through doing the change


Language Setting (only really affects setup menu on the bacic)
Command           lang=n                  
reply                      OK
0=English
                                                                1=French
                                                                2=German
                                                                3=Italian
                                                                4=Danish
                                                                5=Spanish
                                                                6=Finnish
                                                                7=Swedish
                                                                8=Norwegian
                                                                9=Portuguese 

Reset Type
Command           rsttype=n            Reset type  0=Manual    1=Auto  
reply                      OK

Hold Time
Command           holdtime=n        Reset Hold time 1 to 3
reply                      OK

Active from
Command           activef=f.f           Active From  2.0 to 40.0 (default=2.0)
reply                      OK

Mode
Command           mode                    Scrolls between Click, Track & Dial
reply                      OK

Units
Command           bunits                   Scrolls through active units for this capacity
reply                      OK

LCD Contrast
Command           lcdc=n                   LCD Contrast range 1-255 (default=160)
reply                      OK
--------------------------------------------------------------------------------------------------------